Sans 10400 building regulations south africa archid. Studio plus is a small, efficient, cape town based company that has grown and established itself in the architectural and compliance realm. Download the amendments to the sans10400 part x and part xa of 9th september 2011 here. This is the simplest of the three compliance routes, as a competent person energy is not required. According to the approach used in the revised south african building regulations and the new building code sans 10400 series, which should be published early in. Introduction development in the building industry is a continuous process. Sans 10400xa requirements same building shape but sans walls, roof, glazing etc. Electrics archives sans10400building regulations south. Sans 10400 xa, sans 204, health and safety policy, health and safety manual, iso quality manual and other iso documents o n line quote we provide this online quote tool for you. Schedule b is to be completed before plan approval. The sans 10400 part xa new building energy regulations allow for a rational assessment path to compliance under clause 4. Sign, fax and printable from pc, ipad, tablet or mobile with pdffiller. The issuing of our form 4 final signoff for part xa after construction if all of our specifications have been properly implemented in the actual construction, and the required evidence is supplied to us as per appendix a of the quote. In following the prescriptive route, the building must be designed and built in accordance with paragraph 4.
Document downloads building regulations south africa. Sans 10400xa energy usage in buildings urban energy support. Annexes a and d form an integral part of this document. Usually, this is an alternative in the event that the sans 10400 xa prescriptive option somehow poses a lot of technical difficulties.
All new buildings will have to comply with the performance parameters, which means that insulation will have to be installed to achieve the stipulated rvalues. Sanscalc desktop is an easy to use program that is designed to help professionals not only perform sans 10400xa and sans 204 calculations, but also to report on projects for building plan submission, construction and management purposes. The application of the national building regulations part a. Thus, if you wish to comply with the regulations then you have to start with the xa3document which can easily be obtained from za for a. Energy efficiency in buildings the building is so designed that orientation and shading are in accordance with the requirements of sans 204 external walls are in accordance with the detailed requirements of sans 10400 xa fenestration is in accordance with sans 10400 xa. The application of the national building regulations part x. Sans 10400xa and 204 house plans according to sans 10400. Sans 10400xa204 energy efficiency workshop, including. The requirements of this document form part of sans 10400d, sans 10400m and sans 10400t. Thus, if you wish to comply with the regulations then you have to start with the xa3document which can easily be obtained from za for a small fee. Simplicity is the ultimate sophistication leonardo da vinci architecture compliance retail designasbuilt drawings only more is more. It is important to note here that in terms of sans10400xa.
Form the actual wording of regulation xa3, sans 10400 xa is indeed certified to achieve compliance regulations and requirements. The structatherm projects division specialises in the energy modelling of buildings and provides rational design services to customers who are developing new and existing buildings. All new buildings that have been built from the said time of the legislation sans 10400xa published will have to comply with the parameters. Filling in and signing off the certificate of completion form 4 regarding energy. Energy modeling services sans 10400xa sp energy provides energy modeling services to clients who are erecting new buildings or extending existing buildings.
A pdf guide to sans 10400xa we are including a guide on how to comply with the new sans 10400xa regulations. On october 2016 sacap communicated with all registered professionals via an email notice to clarify their. If you go to your local council planning departmant the will have the full selection of forms needed for plan approval. With the passage of time, new materials become available, design methods are refined, and innovative building systems are. By the time the plans are submitted to council, a decision must be made as to which of the.
Energy usage in buildings name of standards organization. A pdf guide to sans 10400xa we are including a guide on how to comply with the new sans 10400 xa regulations. Fully automated data entry user form in excel step by step tutorial. Sans 101775, fire testing of materials, components and elements used in buildings part 5. Energy efficiency in new buildings the energy efficiency legislation for new buildings sans 10400xa has been published by the regulator nrcs. In such a case, the architect or developer may actually decide to use the energy modelling route the reference building route. This document should be read in conjunction with sans 10400a. Compliance with the sans 10400 xa regulations requires that the design of new buildings satisfy certain conditions. We dont think that less is more but strongly believe that only more is more. This standard provides the general requirements for energy efficiency.
Sans 10400xa to avoid repetition, as it is already part of the regulation. The new legislation on energy efficiency for all new buildings sans 10400xa has been published by the nrcs. Sans 10400 the building reference route to compliance. Using certified thermal simulation software, solid green can perform a rational assessment on the existing design.
Municipality contact sans10400building regulations. Sans 10400w, the application of the national building regulations part w. Sans 10400o, the application of the national building regulations part o. We provide basic documentation and contracts templates e.
Compliance with the sans 10400xa regulations requires that the design of new buildings satisfy certain conditions. Professional responsibilities and sans 10400a 2016. Energy modeling services sans 10400xa welcome to sp energy. Even though the new building regulations have been mandatory since october 2008, mid2011 the sabs was still progressively updating its lengthy code of practice. In terms of section 142a of the act this form is to be completed upon the completion of the construction. Building energy modelling prescriptive an alternative to design for sans 10400xa author. Sans10400 form 4 fill online, printable, fillable, blank pdffiller.
Deemedtosatisfy changes looking at the recipe route, as reynolds describes the stepbystep deemedtosatisfy route, she notes that in the current sans 10400 xa, building types that fall in the same category, such as healthcare facilities, are grouped together. American society for testing and materials astm why use the webstore. Sans 10400s sabs 0400s, the application of the national building regulations part s. In terms of section 142a of the act this form is to be completed upon the completion of the. The national building regulations as issued in terms. Approved competent person appointments attach duly completed form 2 to this form. The volume of the annual average hot water heating requirements shall be calculated in accordance with table 2 and 5 of sans 102521 and. Here, the competent person energy efficiency has to make sure that they complete and sign a certification of completion based on the sans 10400 form 4 as soon as the building is finished to make sure that the building has been constructed in accordance with the approved rational design. The workshop has been validated by the sa institute of architects, and will earn 1. National building regulations and building standards act, 1977 act no.